The TOA CM-2330AT is a ceiling-mounted speaker that allows you to select the speaker panel (sold separately) that best suits your installation environment. The spring-catch system allows for easy installation by simply hooking the panel. The plug-in connector allows for one-touch wiring, allowing for both forward and branch wiring. The ATT circuit, which allows for volume adjustment in five stages, uses a transformer, so the attenuation is constant regardless of input, with almost no attenuation during emergency broadcasts.
■Ceiling Speaker
■16cm Type
■3W
■With Volume Control
■Rated Input
■3W
■Rated Impedance
■3.3 kΩ (3W), 10 kΩ (1W)
■Output Sound Pressure Level
■95 dB (1W, 1m, 600 Hz to 6 kHz, pink noise)
■Frequency Response
■90 Hz to 15 kHz (peak -20 dB)
■Speaker Type
■16 cm Cone Type
■Speaker Type
■Class L (92 dB(A) or higher measured with the second signal of the voice alarm according to the Fire Service Act Enforcement Regulations)
■Acoustic Power Level
■94 dB (1W)
■Volume Control
3W/1W Type (Factory-Set to 1W)
■0 dB, -6 dB, -12 dB, -18 dB dB, OFF
■Directivity Classification
W (Q = 5 for 0° to 30°, Q = 3 for 30° to 60°, Q = 0.8 for 60° to 90°)
■Mounting Hole Dimensions
φ200 mm (Maximum Ceiling Thickness: 50 mm)
■Speaker Panel Mounting Method
Spring-catch system (prevents speaker panel from falling off)
■Compatible Wire
600V vinyl-insulated wire (IV, HIV), solid copper wire: φ0.8 to φ1.6 mm
■Speaker Input Terminal
One-touch plug-in connector (supports bridging and branching wiring)
■Operating Temperature Range
-10°C to +50°C ℃
■Other
Complies with JIS C 5532 (Speakers for Sound Systems)
■Finish
Case: Flame-retardant high-impact polystyrene resin (resin material flame-retardant grade: UL94 V-0 equivalent)
Black (approximate Munsell N1.0 color)
■Dimensions
230 (W) x 174 (H) x 95 (D) mm
■Weight
890 g
■Compatible Panels
CP-233A, CP-233B, CP-233W, CP-234A, CP-239A, CP-239W
*Do not cover the speaker with insulation or soundproofing material. Also, install the speaker away from insulation.
*This unit is not weather-resistant. Using it in a humid location prone to condensation, or in a location where the speaker's net surface is exposed to direct water from a shower or other source of water, may cause malfunction.
*Certified under the Fire Service Act when combined with a compatible panel (sold separately) and a system ceiling plate (opening rate of 25% or more, plate thickness of 1.2 mm or less).
*When combined with a compatible panel (sold separately), the product complies with Ministry of Land, Infrastructure, Transport and Tourism specifications.